Are you ready for your next audit?
Whether you are seeking accreditation, preparing for reassessment or surveillance, or simply looking to improve your quality management system, this short questionnaire will help you ask the right questions and avoid potential findings.
As you may have noticed, no two audits are alike. Each auditor is different, and an assessment that is satisfactory one year may result in several findings during the next assessment.
Your quality management system may not have changed significantly, but the questions may have been more relevant and your answers may not have fully convinced the auditor because of insufficient documentation, subjective decisions about the actions to be taken, or difficulty interpreting certain requirements.
This table does not provide solutions when an answer is “No,” “Partially,” or “Not Applicable.” It is your responsibility to revise your documents and provide any necessary clarification.
If a question does not apply to your laboratory, select “Not Applicable” rather than “No” to obtain a more representative chart.
Questions |
Response |
|---|---|
7.8 Reporting of Results |
|
Are results systematically reviewed and authorized before release? |
|
Does the laboratory ensure that reports are accurate, clear, objective, and unambiguous? |
|
Are mechanisms in place to ensure that reports include all information necessary for interpreting the results? |
|
Does the laboratory retain issued reports as technical records? |
|
Does each report include an appropriate title, such as Test Report or Calibration Certificate? |
|
Are the laboratory's name and address clearly stated? |
|
Is the location where laboratory activities were performed identified, particularly for work performed at customer sites or mobile facilities? |
|
Does the report's unique identification ensure that all of its components are recognized as part of a complete document? |
|
Are the customer's name and contact details included? |
|
Is the method used correctly identified? |
|
Are the description and identification of the item, such as a sample or instrument, precise and unambiguous? |
|
Are all relevant dates recorded, including sample receipt, sampling when critical, performance of laboratory activities, and report issuance? |
|
Is a reference to the sampling plan and sampling method included when necessary? |
|
Are results reported with appropriate units of measurement? |
|
Does the report state that the results relate only to the items tested or calibrated? |
|
Are additions to, deviations from, or exclusions from the method documented and explained? |
|
Is the person authorizing the report clearly identified? |
|
When results are provided by external providers, are they clearly identified? |
|
Before issuing an accredited statement of conformity, does the laboratory ensure that all externally provided results are covered by accreditation? |
|
Are controls in place to prevent misuse of the accreditation symbol? |
|
Are reports internally checked or reviewed to ensure compliance with this requirement? |
|
Are specific test conditions, such as environmental conditions, reported when necessary? |
|
Does the report state conformity with requirements or specifications when applicable? |
|
Is measurement uncertainty reported when it is relevant to the validity or application of the results or required by the customer? |
|
Does the laboratory provide opinions and interpretations when appropriate? |
|
If so, are opinions and interpretations clearly distinguished from test or calibration results? |
|
Is documentation available to justify the basis for opinions and interpretations? |
|
When an opinion or interpretation is communicated orally, such as by telephone or during a meeting, how is the discussion recorded? |
|
Are customers informed of the scope and limitations of the opinions and interpretations provided? |
|
If the laboratory does not issue opinions or interpretations, is this stated in its quality management system? |
|
Does the laboratory ensure that only authorized personnel issue opinions and interpretations? |
|
Is there a list of personnel authorized to issue opinions and interpretations? |
|
Is all additional information required by specific methods, authorities, or customers documented? |
|
When results are reported in a simplified manner, is a formal agreement with the customer available? |
|
If certain information required by Sections 7.8.2 through 7.8.7 is omitted from the report, is it readily available? |
|
How does the laboratory ensure that information supplied by the customer is identified in the report? |
|
When customer-supplied information could affect the validity of results, is a disclaimer included in the report? |
|
When sampling was not performed by the laboratory, does the report state that the results apply to the sample as received? |
|
Is there a process for verifying results supplied by external providers before they are incorporated into the final report? |
|
When the laboratory is responsible for sampling, are the requirements of Section 7.8.5 met in test reports? |
|
When the laboratory provides a statement of conformity, is the decision rule used documented? |
|
Does the decision rule take into account the associated risk, including false acceptance, false rejection, and statistical assumptions? |
|
Is the decision rule consistently applied? |
|
Does the laboratory verify that the decision rule is appropriate for customer requirements and applicable standards? |
|
When external results are incorporated into a single report, how does the laboratory ensure that they originate from accredited providers? |
|
Are the conditions defined in Section 6.6 of LAB REF 02 met, including provider evaluation and result traceability? |
|
Does the laboratory clearly distinguish in its reports between accredited and non-accredited statements of conformity? |
|
Are measures such as symbols, explanatory notes, or separate sections used to prevent ambiguity? |
|
When this requirement is not met, does the laboratory correct the affected reports? |
|
Are the results to which the statement of conformity applies clearly identified in the report? |
|
Are the specification, standard, or relevant sections explicitly identified in the report? |
|
Is the applied decision rule stated in the report unless it is inherent in the requested specification or standard? |
|
When there is doubt or significant uncertainty, does the laboratory communicate this information to the customer? |
|
Does the laboratory ensure that any amendment to an issued report is clearly identified? |
|
Are report amendments justified and recorded? |
|
Do reissued reports have unique identification and clearly reference the original report they replace? |
|
Are report amendments marked 'Amendment to Report, serial number…' or with equivalent wording? |
|
Is a person designated to validate and authorize report amendments? |
|
Is there a process to prevent multiple conflicting versions of the same report from coexisting? |
|
Are customers informed of report amendments? |
|
Are measures in place to prevent customers from continuing to use an obsolete version of an amended report? |
|
Have any nonconformities or findings related to report management been identified during internal or external audits? |
|