The ISO 10012 standard had not evolved for 23 years; the transformation is significant and, as with other generic standards (ISO 9001, ISO 14001) and specific standards (ISO/IEC 17025, ISO/IEC 17020), it moves toward a risk-based approach dedicated to the measurement process.
The nomenclature (HLS) is based on ISO 17025; it has shifted from a guide supporting organizations wishing to improve the management of their equipment fleet to a list of requirements, while specifying that "This International Standard is not intended to replace the general requirements for the competence of testing and calibration laboratories specified in ISO/IEC 17025, nor to add requirements to them".
One may raise the question of certification under this standard, which, in my view, is aimed at organizations with a very large equipment fleet and without formal recognition of their metrological management (internal metrology departments of large corporate groups, for example), because managing risk also enables savings on metrological traceability and extending calibration intervals for stable equipment that is non-critical with respect to results.
1. Structure and Overall Approach
The structure now follows the Harmonized Structure for management system
standards (HLS), aligned with ISO 9001 and other management standards. This
includes dedicated sections on the context of the organization, leadership,
planning, support, operation, performance evaluation, and improvement.
2. Context of the Organization
Introduction of a dedicated section on understanding the internal and external
context of the organization (4.1), as well as identifying the needs and
expectations of interested parties (4.2).
This includes particular attention to issues related to climate change and their impact on measurement processes.
3. Leadership and Commitment
Strengthened requirements regarding leadership, with increased
focus on:
- Integrating measurement management system requirements into business
processes.
- Promoting a risk-based approach (5.1 j).
- Explicitly appointing a person responsible for the metrological function,
with clearly defined responsibilities and authorities (5.3).
4. Planning and Risk Management
Introduction of a dedicated section on planning (6),
including:
Identifying and addressing risks and opportunities (6.1), with explicit
management strategies (avoidance, mitigation, transfer, etc.).
Planning measurement management objectives (6.2), with measurability and
relevance criteria.
Managing planned changes (6.3), to ensure system integrity.
5. Support and Resources
Expansion of resource-related requirements (7),
including:
Human resources: Emphasis on competence, awareness, and ethical communication
(7.2, 7.3, 7.4).
Organizational knowledge: Identifying and controlling knowledge necessary
for measurement processes (7.1.5).
Environment and facilities: Taking into account ambient conditions and
their impact on the validity of results (7.1.3).
Software and documented information: Strengthened requirements for control,
validation, and data protection (7.5).
6. Operation of Measurement Processes
Deepening of requirements related to the design, implementation,
and control of measurement processes (8), with:
A stronger process approach, including planning, operational risk control
(8.1.2), and customer communication (8.2.2).
Integration of requirements for external providers (8.4), with enhanced
evaluation and monitoring.
Validation and verification of measurement processes (8.3, 8.5.1.3),
including evaluation of measurement uncertainty and metrological traceability
(8.3.5.4).
7. Performance Evaluation and Improvement
Strengthened requirements regarding:
Monitoring, measurement, analysis, and performance evaluation (9.1),
including customer satisfaction (9.1.2).
Internal audits (9.2), with more rigorous planning and documentation.
Management review (9.3), incorporating more detailed inputs and outputs.
Continual improvement (10), with a systematic approach to handling
nonconformities and corrective actions (10.2).
8. Annexes and Reference Documents
Introduction of informative annexes on:
Optimization of calibration intervals (Annex A), with detailed methods
and strategies.
Measurement uncertainty (Annex B) and measurement decision rules (Annex C),
to enhance result reliability.
Updated normative references: Integration of the latest versions of
ISO/IEC Guide 98, ISO 9000, ISO 17034, etc.
9. Terms and Definitions
Update and expansion of definitions, particularly for:
Measurement management system (3.19.4) and measurement process (3.19.2).
Risk (3.7), measurement uncertainty (3.19.1), and metrological traceability
(8.3.5.4).
External provider (3.21) and metrological confirmation (3.22).
10. Focus on Uncertainty and Traceability
Measurement uncertainty is now a central element, with explicit requirements
for its evaluation, documentation, and integration into decision rules
(Annex C).
Metrological traceability is reinforced, with mandatory reference to the SI (International System of Units) or consensus standards (8.3.5.4).
11. Integration of New Technologies
2026: Consideration of issues related to cybersecurity, data protection,
and the use of software and digital systems in measurement processes
(7.1.4, 7.5.3).
12. Strengthened Requirements for External Providers
External providers (subcontractors, laboratories, etc.) are subject to
increased control and monitoring requirements, including audits and
documented evaluations (8.4).
Summary of Impacts for Your Laboratory:
Strategic alignment: The 2026 standard encourages
stronger integration of the measurement management system into the
organization's overall strategy.
Risk-based approach: Proactive management of risks
and opportunities is now required, using documented methods.
Traceability and uncertainty: The emphasis on
measurement uncertainty and traceability strengthens result reliability and
compliance with customer/regulatory requirements.
Continual improvement: Audit, management review,
and corrective action processes are formalized to ensure ongoing
improvement.
Conclusion:
I am accredited under ISO/IEC 17025; what should I do with all this information and these requirements?
Use what makes sense for your organization and identify natural bridges between the impacts.
For example:
1/Risk-based approach to the verification of my equipment (risk mapping of critical processes, direct or indirect impact, daily/weekly monitoring, calibration history, control charts) using a proven method (FMEA, OPPERET, Statistics) Annex A.4.4 Existing approaches.
2/ Integration into the organization's overall strategy through a strategic alignment of policy (opportunities, cost savings achieved, optimization of fleet management) --> management involvement.
3/ Define decision rules on accounting for uncertainty to reduce the risk of incorrect decisions.
4/ Continual improvement is already embedded in accredited organizations; in this case, it is aimed more at calibration or verification bodies, for whom customer satisfaction can be focused on measurement processes.
For my part, I will work on a decision-making logic based on an interval-determination algorithm using indicators according to the AHP (Analytic Hierarchy Process) method, which I will apply to equipment and interlaboratory comparisons (see calculation sheets).
Note that some standards mandate a verification schedule (e.g., 12 months maximum); there is no point in working on such equipment, as it is harder to justify during audits with respect to the normative requirement.
Topic |
Concrete
Action |
Expected
Benefit |
| Measurement
uncertainty |
Apply decision rules
(e.g., guard bands) for a critical test. |
Reduction of incorrect
decision risks. |
Risk
management |
Map risks of critical
processes (e.g., calibration of reference standards). |
Error reduction and
improved reliability. |
Calibration
intervals |
Optimize intervals for
2 stable instruments (e.g., calipers). |
Cost reduction without
loss of quality. |
External
providers |
Audit a key subcontractor
(e.g., calibration laboratory). |
Control of risks related
to the traceability chain. |
Customer
satisfaction |
Launch a satisfaction
survey on calibration services. |
Identification of areas
for improvement. |
Traceability |
Centralize calibration
certificates in a database. |
Time savings for audits
and compliance. |