Can any laboratory apply for accreditation?
Are laboratories accredited to ISO/IEC 17025 also compliant with ISO 9001?
4.1.2 - How does laboratory management ensure that activities are carried out impartially?
4.2.1 - Do confidentiality requirements apply to all laboratory personnel?
4.2.2/4.2.3 - May a laboratory disclose results to third parties not directly involved in the service?
5.1 - What does “legally responsible” mean?
5.2 - Who constitutes laboratory management?
5.4 - What is meant by the range of laboratory activities?
5.4 - How should activities performed at customer facilities be understood?
5.6/5.7 - Must the laboratory appoint deputies for every management function?
6.2.4 - How should duties, responsibilities, and authorities be communicated to laboratory personnel?
6.3 - Must laboratories monitor, control, and record environmental conditions?
6.4.1 - Is software considered laboratory equipment?
6.4.8 - Must equipment subject to calibration or periodic checks be labeled to indicate its status?
6.4.13(f) - How should I manage reference materials, certified solutions, reference blocks, and similar items?
6.4.13(g) - When is a maintenance plan needed, and what should it include?
6.5.2(a) - What does the standard mean by a competent laboratory?
6.5.2(a) - What types of services and supplies fall under this requirement?
6.6 - My laboratory uses an external equipment calibration service but no other supplies or consumables for tests within its scope. Does clause 6.6 apply?
6.6 - Must we record the measures taken to verify the conformity of received supplies, services, and consumables?
6.6 - Should interlaboratory comparison providers be considered critical suppliers?
6.6 - What do assessors look for in purchasing documents to evaluate compliance with this requirement?
7.1.3/7.8.6.1 - What is a decision rule when a customer requests a statement of conformity?
7.2.1.4 - Can a laboratory be accredited for nonstandard methods developed in-house?
7.2.1.5 - If a customer specifies a nonstandard method during contract review, must the laboratory validate it under ISO/IEC 17025 clause 7.2.2?
7.3 - Does this clause apply if we test only a portion taken from a larger sample provided by the customer?
7.3 - Does the sampling clause apply to my laboratory?
7.4 - If a received sample does not meet the conditions needed for reliable testing, must this be stated in the report?
7.4 - Is continuous monitoring required when items are stored or conditioned for extended periods under specified environmental conditions?
7.5 - Must a laboratory retain all original observations?
7.5 - How much detail must be retained in technical records?
7.6 - If a testing laboratory only conducts tests that do not require an estimate of measurement uncertainty, does this requirement still apply?
7.7 - If my laboratory participates successfully in interlaboratory comparisons for its accredited tests, have we met the validity-monitoring requirements?
7.7 - Are all the activities listed in clause 7.7.1 mandatory?
7.7 - What should my laboratory do to meet this clause?
7.8 - Must accredited laboratories display the COFRAC logo on test reports and/or calibration certificates?
7.8 - I do not issue a statement of conformity, but the customer provided tolerances and the result is close to a limit. Must I report measurement uncertainty even if not requested?
7.8 - Is it necessary to identify the revision date of the test method?
7.8 - Is a handwritten signature required?
7.8 - Does electronic transmission of results require additional security measures?
7.8 - Must all information listed in clauses 7.8.2.1(a) through (p) appear in every report?
7.8 - My customer supplies a mechanical property used in a formula to calculate the fracture toughness parameter K1c after fatigue testing. Must this be disclosed in the report?
7.8 - I am reissuing a report because the technician transposed two lot numbers. Must the revised report identify the change?
7.8.7 - May opinions and interpretations be included in a report issued under accreditation?
7.9 - What constitutes a customer complaint?
7.10 - A technician identifies a recurring error in a report that has no significant impact on the current service. What should be done?
7.11 - What is required to validate software? Must commercially available software also be verified?
7.11 - We outsource laboratory network hosting and document archiving. What precautions should we take?
8.1 - If a laboratory belongs to a larger organization with its own quality system, is a separate ISO/IEC 17025 management system required?
8.1 - How detailed must the laboratory quality management system be?
8.2.1 - How can a laboratory demonstrate that its management system documentation was communicated and is properly implemented by personnel?
8.2.1 - What evidence shows that personnel understand the relevance and importance of their activities?
8.2.3 - Must the laboratory evaluate its effectiveness against its objectives?
8.2.3 - What constitutes evidence of management commitment?
8.3 - Must all forms used by the laboratory undergo document review?
8.3 - What are “normative documents” that my laboratory must control under its document management system?
8.3 - If we keep a single centralized, controlled copy of all management system documents, is a distribution list necessary?
8.3 - How much time does a laboratory have to implement revisions to COFRAC documents?
8.3 - How should new or revised text be identified, and when might doing so be impracticable?
8.4 - How long must records be retained?
8.5 - What risks might my organization face?
8.5 - What actions should my organization take in response to risks and opportunities?
8.6 - How can a laboratory collect customer feedback, and how should it analyze the comments?
8.7 - Is a laboratory’s cause analysis deficient if it does not identify the root cause?
8.7 - What does it mean to evaluate whether corrective action is needed?
8.7 - Must my laboratory maintain records demonstrating follow-up on corrective actions?
8.8 - Must my laboratory audit its entire management system and all activities every year?
8.8 - Before initial accreditation, must a new laboratory complete an internal audit of its management system and testing activities?
8.8 - Can an external audit replace all or part of a laboratory’s internal audit?
8.8 - Does the internal auditor need specific training in ISO/IEC 17025?
8.9 - Must a laboratory complete a management review before obtaining initial accreditation?